Prepare a floor plan and evacuation draft

Use a room or floor scan to prepare and check a floor plan. Then add the evacuation information that has been confirmed.

4 min readUpdated

From a scanned floor to a plan

An earlier CADground task used scan points and views with a known scale to prepare a floor plan and PDF. A later task added a “You are here” marker at the user’s chosen location. It proposed routes to a central stair. The outdoor exit and assembly point were not confirmed, so the evacuation plan remained a draft.

A floor plan shows the scanned layout. An evacuation plan also needs confirmed exits, routes, and site procedures. The scan may not contain that information.

Gather the inputs

  • The correct floor’s scan, with units and a known dimension.
  • The intended floor/level and a way to distinguish it from overlapping floors.
  • Room names, door information, and any existing approved plan or drawing.
  • For the evacuation draft: confirmed exits, usable routes, stairs, the plan’s display location and direction, and the assembly point.
  • The exact location for “You are here”. Supply a marked image and a description of the physical position.

1. Identify the floor and coordinate frame

Inspect the scan and identify the correct floor. Find its elevation. Use the building geometry to choose a useful plan-view direction. Keep the source coordinates unchanged. Record any changes made for the report view. Mark areas where other floors overlap.

Rotating the report view does not require rotating the model away from the scan. Record how the plan image relates to the original scene. You will need this information to check measurements and compare later CAD models.

2. Reconstruct the visible layout

Prepare a floor plan from this scan. Identify continuous walls, visible openings, stairs, and room boundaries. Check whether each gap is an opening or missing scan data. Mark uncertain boundaries. Do not invent hidden wall thicknesses or connections between rooms.

  1. Check the selected floor with a top/orthographic view and supporting side views.
  2. Inspect the wall points and main corners before drawing lines.
  3. Check that each door connects the correct spaces. A gap caused by a hidden surface is not proof of a doorway.
  4. Include a scale/reference dimension and use consistent units.
  5. Ask for an image with the floor plan over the scan. Use it to compare each boundary with the source points.

3. Check the floor plan

Check opening widths, room connections, the stair location, and inaccessible areas. Compare the plan with the scan using the same view and scale. Keep uncertain boundaries marked, even if the drawing looks complete.

Show the floor plan over the source scan. Check doorway widths and room connections. List every boundary that is inferred or uncertain. Save the reviewed plan as an image and PDF. Include the scale and source information.

4. Add an evacuation overlay

Start this step only after checking the layout. Supply the confirmed exits, routes, and site procedures. State where the printed plan will be displayed and which direction it will face. The “You are here” marker and plan direction must match that location.

Add a draft evacuation overlay to the reviewed floor plan. Place “You are here” at my marked location. Use only the exits and routes I have confirmed. Mark unconfirmed route sections and destinations as unresolved. Include a legend, direction reference, source, and revision. Clearly label the plan as a draft.

In the earlier task, the central stair was a proposed destination. A complete safe route to an outdoor exit had not been confirmed. Ask the responsible reviewer to check the full route, final exit, assembly point, assistance arrangements, and site procedures.

Requirements depend on the site and its location. For example, UK government guidance on evacuation planning covers escape routes, exits, meeting points, and help for people who need assistance. Apply the rules for your site and have a qualified person review the plan. A generated drawing alone does not confirm compliance.

5. Download and review the actual files

  1. Ask the built-in agent to save a PDF and image for review. Ask for SVG if you need to edit the drawing as vectors.
  2. Open Files → Outputs and select the named files.
  3. Inspect the PDF at its intended print size. Check labels, line weights, symbols, route visibility, scale, and orientation.
  4. Check that “You are here” matches the location where the plan will be displayed.
  5. Keep the plan marked as a draft until all exits, routes, destinations, and required approvals are confirmed.

The agent can generate an SVG or PDF drawing. This is not native DWG/DXF export. It does not automatically produce a certified evacuation plan.